Chat with us, powered by LiveChat

Professional & Reliable Service

We strongly recommend you get your boiler serviced once a year to keep it running efficiently and safely. A faulty boiler could not only waste your money on energy bills, but it might even start leaking poisonous carbon monoxide through cracked heat exchanger. Because the Carbon monoxide gas is colourless and scentless, it’s hard to tell if one of your appliances starts leaking.

You don’t need to be a Boilerman customer to book your service with us. Our annual service plans are very affordable way to get worry-free maintenance on your boiler systems. We offer exclusive discounts on products and services, priority service, and much more…

  • We’ll perform the gas pressure test.
  • We’ll perform the gas dial test to make sure complete burning of fuel gases.
  • We’ll inspect your boiler & its control system to make sure they’re working properly.
  • We’ll check your boiler for corrosion and leaks through heat exchanger.
  • We’ll take off the front casing of your boiler to inspect the main components & clean if necessary.
  • We’ll pop the casing back on and check the seals.
  • We’ll test the flue gases make sure it’s not emitting any Carbon monoxide.
  • We’ll leave you with a complete checklist of information about your boiler’s safety.
  • Platinum Members Plan
  • Gold Members Plan.
  • Silver Members Plan.

24/7 SERVICE,
365 DAYS A YEAR

24/7 service including holidays, no overtime charges to our clients.

PROUDLY SERVING FOR
OVER 60 YEARS

All our technicians holds the required license & a minimum of 10 years experience on their belt.

PERSONALIZED SOLUTIONS &
INDIVIDUAL ATTENTION

We have the highest standards when it comes to installation or service delivery.

Services We Offer

BOILERS INSTALLATION/SERVICE

  • Floor Mounted Boiler
  • Wall Hung Boilers
  • Combination Boilers
  • Indirect Water Tanks
  • Taco/Watts Honeywell Techmar

INFLOOR & RADIATORS

  • Cast Iron Radiators
  • Panel Type Radiators
  • Compact & Plan Compact Radiators
  • Baseboard Panel Radiators
  • Towel Warmer & More

SPACEPAK & DUCTLESS SYSTEMS

  • No Tear Down Of Walls
  • Draft Free Premium Air Circulation
  • Remove Over 30% Humidity
  • Virtually No Sound
  • Energy Saving Temperature Zoning

SILVER PLAN

  • Perform scheduled boiler inspections as part of a maintenance contract.
  • Carry out routine planned, predictive maintenance tasks including Vent Inspection & Combustion Air Calculation and inform the building/home owner on the state of boiler
  • Check temperature readings and pressure guages/ readings to make sure all are within the designed range as specified by the equipment manufacturer.
  • Check gas leaks through the gas line or boiler gas valve, gas train and manifold.
  • Examine and clean flame sensors, ignitor, and burner assembly.
  • Collect Carbon Monoxide reading with Electronic Combustion Gas Analyzer to make sure the boiler CO LEVEL is below the industrial standards for safety of occupants.
  • Jot down & Check Error Codes or History of Error Codes if any.

GOLD PLAN

  • Perform scheduled boiler inspections as part of a maintenance contract.
  • Carry out routine planned, predictive maintenance tasks including Vent Inspection & Combustion Air Calculation and inform the building/home owner on the state of boiler
  • Check temperature readings and pressure guages/ readings to make sure all are within the designed range as specified by the equipment manufacturer.
    Check gas leaks through the gas line or boiler gas valve, gas train and manifold.
  • Examine and clean flame sensors, ignitor, and burner assembly.
  • Collect Carbon Monoxide reading with Electronic Combustion Gas Analyzer to make sure the boiler CO LEVEL is below the industrial standards for safety of occupants.
  • Jot down & Check Error Codes or History of Error Codes if any.
  • Take water samples from customers’ steam systems for analysis.
  • Perform basic water treatment testing/ PH-Level of the boiler water program and report conditions to clients. Check Glycol Concentration in closed loop system & make sure the system would not freeze during no call for heat.
  • Perform troubleshooting of equipment & accessories including Pressure Relief Valve and discharge pipe for signs of weeping, BFP Valve failure, Check Valve failure , AFV failure to monitor the make up water while running the burner , Blow down LWC, & check the Pumps condition.

PLATINUM PLAN

  • Perform scheduled boiler inspections as part of a maintenance contract.
  • Carry out routine planned, predictive maintenance tasks including Vent Inspection & Combustion Air Calculation and inform the building/home owner on the state of boiler
  • Check temperature readings and pressure guages/ readings to make sure all are within the designed range as specified by the equipment manufacturer.
  • Check gas leaks through the gas line or boiler gas valve, gas train and manifold.
  • Examine and clean flame sensors, ignitor, and burner assembly.
  • Collect Carbon Monoxide reading with Electronic Combustion Gas Analyzer to make sure the boiler CO LEVEL is below the industrial standards for safety of occupants.
  • Jot down & Check Error Codes or History of Error Codes if any.
  • Take water samples from customers’ steam systems for analysis.
  • Perform basic water treatment testing/ PH-Level of the boiler water program and report conditions to clients. Check Glycol Concentration in closed loop system & make sure the system would not freeze during no call for heat.
  • Perform troubleshooting of equipment & accessories including Pressure Relief Valve and discharge pipe for signs of weeping, BFP Valve failure, Check Valve failure , AFV failure to monitor the make up water while running the burner , Blow down LWC, & check the amperage & Pumps condition.
  • Perform thorough inspectioin & testing of your control systems including flushing and draining Low Water Cutoff system, Inspect motor and end switch Honewell Zone Controls , check the electrical connection and rating Taco 3-wire Zone Controls, inspect ZVC 401-3 controls , Taco Switching Relays SR 1-2 & run the complete cycle to ensure all control systems are running properly. Recalibrate all operating Controls as per manufacturer specifications.
  • Tekmar Switching Relays Control, aquast at calibration , indirect DHW configuration or infloor hydronic controls will be charged separately if required.